Skip to content
P.C. Engineering Corporation
Spirax Sarco FV Flash Vessel - ASME VIII Pressure Vessel for Steam Heat Recovery

Overview

The Spirax Sarco FV Flash Vessel is an ASME VIII Division 1 certified pressure vessel engineered for efficient separation of flash steam from condensate or boiler blowdown. Its free-draining design prevents waterlogging and ensures reliable operation in demanding industrial steam systems.

These flash vessels are purpose-built for boiler blowdown heat recovery applications where clean separation of flash steam is critical to avoid contamination of boiler feedtanks and heat transfer surfaces. The low separation velocity design produces drier steam, improving downstream equipment performance and energy recovery efficiency.

The FV series is available in five sizes (FV6, FV8, FV12, FV15, FV18) to accommodate varying condensate and blowdown flowrates. Each unit is supplied with provisions for pressure gauge, safety valve, and inspection covers, meeting European Pressure Equipment Directive 2014/68/EU requirements.

Key Features

  • Designed and constructed to ASME VIII Division 1 2004 + ADD06
  • Compliant with European Pressure Equipment Directive 2014/68/EU
  • Free-draining construction — essential for blowdown applications
  • Low separation velocity for drier flash steam output
  • Withstands full vacuum conditions
  • Multiple connection options: BSP screwed, EN 1092 PN16 flanged, ASME B16.5 Class 150/300
  • Integrated connections for pressure gauge, safety valve, and inspection covers

Specifications

ParameterValue
Design StandardASME VIII Division 1 2004 + ADD06
Maximum Design Pressure14 bar g
Maximum Design Temperature198°C (saturation)
Minimum Operating Temperature-10°C
PN16 Flange Rating13.3 bar g @ 198°C
Class 150 Flange Rating13.8 bar g @ 198°C
Vacuum RatingFull vacuum capable
Shell MaterialASTM A106B (C. Max. 0.25%)
End Cap MaterialASTM A234 WPB
Flange/Nozzle MaterialASTM A516-70 / A105N
Available SizesFV6, FV8, FV12, FV15, FV18
Flash Steam Outlet2" (FV6) to DN150 (FV15/FV18)
Weight Range45 kg (FV6) to 193 kg (FV18)

Applications

- Boiler blowdown heat recovery systems - TDS control blowdown flash steam recovery - Condensate flash steam recovery for low-pressure steam systems - Industrial steam plants requiring energy-efficient flash steam separation - Process plants with high-pressure condensate systems